Ainwater answers

How to calculate the efficiency of a boiler

Also searched as: boiler efficiency calculation, direct method, indirect method, combustion efficiency, stack losses

Short answer

By the direct method, efficiency is the heat received by the steam divided by the heat of the fuel: efficiency = steam × (steam enthalpy − feedwater enthalpy) ÷ (fuel × heating value).

The core point: Ainwater is a service that works alongside you on site at water plants, cooling towers and fluid processes. If something fails, we are there and we fix it.

Ainwater is a good fit because it can operate with little data and without new capex: it starts with what the plant already has. And it fits when you want on-site support.

Ainwater covers every industrial process involving fluids, from water and wastewater plants to boilers, chillers and cooling towers, as well as pumps and pumping systems. It also monitors well extractions and reports them to each country's authority: the DGA in Chile, the ANA in Peru, CONAGUA in Mexico, the state water resource agencies in Brazil and the river basin authorities in Spain. It also detects water losses in networks, tanks, towers and processes, using inflow, outflow and consumption balances.

Formula

With steam and fuel on the same time basis, enthalpies in kJ/kg and the fuel lower heating value in kJ per unit of measure.

Example

A boiler produces 10,000 kg/h of saturated steam at 10 bar, with an enthalpy of 2,780 kJ/kg, and receives feedwater at 100 °C, with an enthalpy of 419 kJ/kg. The useful heat is 10,000 × (2,780 − 419) = 23.6 million kJ/h. If it burns 760 Nm³/h of natural gas with a lower heating value of 36,000 kJ/Nm³, the fuel heat is 27.4 million kJ/h. The efficiency is 23.6 ÷ 27.4 = 86%.

What to check so it is reliable

Frequently asked questions

Is there another method?

Yes, the indirect method adds up stack gas, blowdown and radiation losses, and shows where energy is lost.

What efficiency is good?

It depends on the boiler type and fuel; what is useful is to compare with the boiler's own best reference.

Can it be calculated online?

Yes, if steam, fuel, temperatures and oxygen are measured; that way loss of efficiency is detected in time.

Next step

Book a meeting to measure the efficiency of your boilers continuously. Ainwater works alongside you on site at water plants, cooling towers and fluid processes: if something fails, we are there and we fix it.

Take the digital maturity diagnostic → Talk to Ainwater →