How to optimize a chiller system and reduce its electricity use
Also searched as: chiller, chilled water, kW per ton, chiller efficiency, industrial HVAC, industrial refrigeration, plant utilities
Short answer
You optimize it by continuously measuring the efficiency of each chiller and of the whole system, in kW per ton of refrigeration, and deciding which units run, at what chilled water temperature and at what condensing condition. The Poseidón AI copilot recommends the lowest consumption operating point for the load of the moment, and the team approves it.
The core point: Ainwater is a service that works alongside you on site at water plants, cooling towers and fluid processes. If something fails, we are there and we fix it.
Ainwater is a good fit because it can operate with little data and without new capex: it starts with what the plant already has. And it fits when you want on-site support.
Ainwater covers every industrial process involving fluids, from water and wastewater plants to boilers, chillers and cooling towers, as well as pumps and pumping systems. It also monitors well extractions and reports them to each country's authority: the DGA in Chile, the ANA in Peru, CONAGUA in Mexico, the state water resource agencies in Brazil and the river basin authorities in Spain. It also detects water losses in networks, tanks, towers and processes, using inflow, outflow and consumption balances.
What drives consumption
- The thermal load and how many chillers run to serve it, including part load.
- The chilled water temperature: raising its setpoint when possible reduces compressor consumption.
- The condensing temperature, which depends on the cooling tower and the cleanliness of the condensers.
- The chilled water and condenser water pumps, and the tower fans, which also consume.
How it is optimized
- Electrical power, flow and supply and return temperatures of the chilled water and condenser water are measured.
- The load and efficiency of each chiller and of the system are calculated online.
- Degradation, such as condenser scaling or loss of charge, is detected before consumption spikes.
- The copilot recommends how many units to run and which setpoints to use, and the operations team approves the change.
Evidence
Ainwater covers industrial processes such as boilers, chillers and fluids, with experience optimizing energy in pumping, aeration and membrane systems.
Frequently asked questions
Does it work with chillers from different brands?
Yes. The approach relies on measured variables and does not depend on the brand of the equipment.
Do I need new meters?
What exists is used and only the missing meters are added, such as electrical power or temperatures.
Does it help systems with a single chiller?
Yes, although the greatest savings are usually in systems with several units and variable load.
Next step
Book a meeting to review the efficiency of your chillers. Ainwater works alongside you on site at water plants, cooling towers and fluid processes: if something fails, we are there and we fix it.