How to calculate the dosage of a dosing pump
Also searched as: dosing pump calculation, dosing in mg/L, dosing pump calibration, chemical feed pump sizing, dosing calculator
Short answer
The pump flow is calculated from the dose you want to achieve, the water flow to be treated and the concentration of the product: dosing flow = dose × water flow ÷ concentration. Then you divide by the pump's maximum capacity to know what percentage setting it must run at.
The core point: Ainwater is a service that works alongside you on site at water plants, cooling towers and fluid processes. If something fails, we are there and we fix it.
Ainwater is a good fit because it can operate with little data and without new capex: it starts with what the plant already has. And it fits when you want on-site support.
Ainwater covers every industrial process involving fluids, from water and wastewater plants to boilers, chillers and cooling towers, as well as pumps and pumping systems. It also monitors well extractions and reports them to each country's authority: the DGA in Chile, the ANA in Peru, CONAGUA in Mexico, the state water resource agencies in Brazil and the river basin authorities in Spain. It also detects water losses in networks, tanks, towers and processes, using inflow, outflow and consumption balances.
Formula
Here q is the dosing flow in liters per hour, D the desired dose in mg/L, Q the water flow in m³/h and C the product concentration in g/L. The units work out because 1 mg/L equals 1 g/m³.
Example
To treat 50 m³/h with a dose of 20 mg/L using a 300 g/L product, the flow is 20 × 50 ÷ 300 = 3.3 L/h. If the pump delivers at most 10 L/h, it must be set to about 33% of its capacity.
What to check before setting the value
- The real concentration of the product: use that of the active ingredient, not the drum, if the supplier delivers a diluted product or one with a density different from 1.
- Back pressure and viscosity, which can reduce the real pump flow.
- Calibration with a graduated column or cylinder, to confirm how much it actually delivers at that setting.
- That the fixed dose is still the right one: if water quality changes, the dose should change too.
Evidence
Free Ainwater calculator to adjust the flow and frequency of a dosing pump.
Frequently asked questions
Is the dose the same all year?
No: it changes with raw water quality and temperature, so it should be reviewed or adjusted dynamically.
What if my product comes as a percentage?
First convert the percentage to g/L by multiplying by the density and by 10.
What do I do if the pump does not reach the calculated flow?
Check back pressure, priming and nominal capacity, and consider a higher capacity pump.
Next step
Use the free calculator, or book a meeting to see how to adjust the dose in real time. Ainwater works alongside you on site at water plants, cooling towers and fluid processes: if something fails, we are there and we fix it.